25kV Equipment (Urban Systems)

Section 1

1x 25kV input compartment:

  • Compartment 1 – 25kV switch
    • 3x LED voltage indicators (connected to input terminals)
    • 3x surge protector (Distribution Class – Heavy duty) (connected to the switch input)
    • Load switch 25kV 600A (without fuse)
    • 1x AC control transformer 25000V/120V protections
    • Primary and secondary fuses
    • Recessed handles to prevent breakage during transport.
    • Window (safety glass) for displaying the status of the switch contacts
    • Cable entry from the top or bottom/side via connection box
  • Compartment 2 – 25kV circuit breaker
    • Fixed vacuum circuit breaker 25kV 16kA 600A electrically operated
    • Opening device in the event of undervoltage (opening of the circuit breaker if the control voltage is lost)
    • Overcurrent protection made by the protection relay (installed in the control compartment)
    • Kirk-key interlock between the 25kV switch door, the circuit breaker door and the switch handle to prevent opening under voltage
    • Window (safety glass) for viewing the circuit breaker

Section 2

Transformer 24940V / 4160/2400V “Delta-Wye” including:

  • Power: see the selection table
  • 150 C Rise
  • Adjustment rate: 4x 2.5% (2FCAN+2FCBN)
  • 3x surge protector (Distribution Class – Heavy duty)
  • 1x temperature monitor with opening/alarm contacts (control section)
    • § Programmable microprocessor controller
    • RS-485 (Modbus ASCII/RTU) Communication
    • § Alarm #1 – 100°C – Alarm temperature (dry contact)
    • §Alarm #2 – 170°C – Alarm temperature (dry contact)
    • § Alarm #3 - 200°C – High temperature alarm (dry contact)
    • § Type “J” thermocouple installed in the transformer
    • § 12x cooling fans (automatic mode)

Section 3

1x 5kV transfer switch (power supply from transformer or external generator):

  • Switch without fuse 5kV 600A
  • Kirk-key interlock between door and switch to prevent opening under power;
  • Interlock Kirk-key between the 2 source positions
  • Interlock Kirk-key between the 2 compartment access
  • Recessed handles to prevent breakage during transport.
  • Window (safety glass) for displaying the status of the switch contacts

1x 5kV secondary feeder (with earth fault detection and ground continuity – ground fault/ground check):

  • 5kV 600A switch with “backup” type fuses (3x 200A)
  • 1x 5kV vacuum contactor
  • Earth fault/mass continuity detector (installed in control compartment) with CT
  • Ground continuity supervision resistor (to be installed in the tunnel boring machine by you)
  • Recessed handles to prevent breakage during transport.
  • Window (safety glass) for displaying the status of the switch contacts
  • Removable plate for installation of the 5kV PLM socket on site by you

1x 5kV secondary artery:

  • 5kV 600A switch with “backup” type fuses (3x 200A)
  • Kirk-key interlock between door and switch to prevent opening under power;
  • Recessed handles to prevent breakage during transport.
  • Window (safety glass) for displaying the status of the switch contacts

Enclosure including:

  • Drip-proof housing
  • Cabinet cleaned with sandblasting and gray epoxy paint;
  • Approximate dimensions:
    • 104’’ H x 90’’ D x 270’’ W
    • Approximate weight: 35,000 pounds